MICRO MEGA HERO SHAPER INDIVIDUAL MANUAL FILES

₹1,720.00
availability: In Stock

  • Nothing

Description

Using HERO Shaper® for orthograde treatment has never been quicker and simpler. Conditions such as irreversible pulp pathology, pulpitis and necrosis are easily managed using the HERO Shaper® rotary nickel -titanium instruments at low speed.

HERO Shaper® files, with their pronounced tapers, are designed for use with the crown-down technique to progressively remove constraints and flare the canal. The coronal third is prepared using .06 taper HERO Shaper® files and the apical third is prepared using .04 taper HERO Shaper® files. The varying helical pitch and length of the cutting portion of the files provide them with an excellent combination of efficiency and flexibility.

Key Specifications
2 Files Shaping System
Avoids screwing effects: helical angle varies from tip to shank
Time saving: 10s of use per instrument for efficient shaping
Less instruments to handle

Indications
Yellow sequence

Difficult canals, severely curved, possibly with significant hypercalcification, making any first penetration tricky with the finest hand files.
Speed 300 to 600 rpm

Red sequence

Canals of average difficulty with moderate curvature and/or more hypercalcification, making first penetration with a n 10 K file harde to achieve.
Speed 300 to 600 rpm

Blue sequence

Easy canal preparation, low curvature, orifice and canal large enough to allow a n 15 K file to reach the Apex.
Speed 300 to 600 rpm

Features
An innovative pitch:

A positive advance in root canal preparation:

This root canal treatment method is faster and allows:

Avoids screwing effects: the helical angle of the cutting edges varies from the tip to the shank.
The new pitch also varies according to the taper: the more tapered an instrument is, the longer is its pitch; This can be described as an ADAPTED pitch. Increased instrument performance :
The blade shows a triple helix cutting edge.
The tip is inactive in order to follow the canal anatomy.
Improved patient comfort.
Time saving : 10 seconds of use per instrument for efficient shaping.
Reduced operator fatigue.
Less instruments to handle.
Reproducible results.
Increased safety:

Anti Breakage Control: the instrument unwinds to prevent the risk of fracture.
no screwing effect.
excellent debris evacuation.

Reviews

No reviews have been written for this product.

Write your own review

Opps

Sorry, it looks like some products are not available in selected quantity.